Precision Controls
   P.O. Box 670
 Ruskin FL. 33575-0670
 Phone: 813-480-7346  Fax: 813-641-9295
 Email: Info@PrecisionControls.net
Home EMEC FloMotion Pan World Myron L. Additional Services Contacts

EMEC Americas


  Sensors    Chemical Feed Pumps   Controllers  Accessories

Systems 1


Sensors: pH and ORP ElectrodespH and ORP Electrodes

Systems 2

DATA Sheets for Engineering Specifications and Operation Manuals available upon request in PDF format..

Systems 3


Turbidity Scattered Light Sensor:

Turbidity Scattered Light Sensor:

pH and ORP Electrodes

  • pH (0 – 14) and ORP (0 – 1,000) Electrodes
  • Operation Range: 101 PSI (7 Bars) at 158 ̊F (70 ̊C)
  • 3’ to 150’ Cable with Built-In Amplifier
  • BnC Connections for easy installation to Pumps or Controllers
  • Minimum 100µS

Models:

  • Standard Glass Cell
  • Double-Junction
  • Self-Cleaning
  • Submersible
Materials:
  • Epoxy Body
  • PVC

Amperometric Soft Membrane Cap Electrodes

Amperometric Soft Membrane Cap Electrodes

  • Semi-Permeable Membrane Cap

  • NO Vinegar (pH Compensated from 6.8 – 8.0 pH* or 5.0 – 9.0 pH**)

  • Temperature Compensated from 0 – 10  ̊F Daily

Operation Range:

  • UP to 15 PSI (1 Bars)
  • Max. Flow 10 GPH (40 LPH)

Applications:

  • Potable Water
  • Wastewater
  • Seawater

  • Pools and Spas

Models: ECL x/x :

  • Free Chlorine 0 – 2, 0 – 5, 0 – 20, and up to 200 ppm *
    (Organic or Inorganic Available)
  • Free Chlorine Seawater) 0 – 2 and up to 20 ppm *
  • Chlorine Dioxide 0 – 2, 0 – 10, and up to 20 ppm
  • Total Chlorine 0 – 2 and up to 20 ppm**

  • Total Chlorine Seawater 0 – 2 and up to 20 ppm**
  • Hydrogen Peroxide 0 – 200 and up to 2,000
  • Ozone 0 – 1 and up to 10 ppm
  • Peracetic Acid 0 – 200 and up to 2,000 ppm
  • Turbidity 0 – 100 and up to 1,000 NTU

HIGH PRESSURE Amperometric Membrane Cap Electrode:

HIGH PRESSURE Amperometric Membrane Cap Electrode:

  • NO Replacement Membrane Cap Needed

  • NO Vinegar (pH Compensated from 6 – 8 pH)

  • Temperature Compensated from 0 – 10  ̊F Daily

  • Saves 135,000 Gallons of Water Annually (NO DUMPING TO DRAIN)

Operation Range:
  • UP to 125 PSI (8 Bars)
  • Max. Flow 10 GPH (40 LPH)

Models: ECL x/x :

  • Chlorine 0 – 10 ppm
  • Chlorine Dioxide 0 – 10 ppm

Amperometric Open Cell Electrodes:

Amperometric Open Cell Electrodes:

Great for Pools and Spas

  • NO Vinegar (pH Compensated from 6 – 8 pH)

  • Temperature Compensated from 0 – 10  ̊F Daily

  • Organic (liquid) and Inorganic (stabilizers)

  • Saves 135,000 Gallons of Water Annually (NO DUMPING TO DRAIN)
     


Conductivity Electrode
Conductivity Electrode:

 

  • High Linearity

  • Available PT100 (RT) Temperature Compensation

  • Insertion Glands Available in ½” and ¾” NPT

  • Standard 14.5’ Cable (4.5m)

  • Operation Range UP to 101 PSI (7 Bars) at 158 ̊F (70 ̊C)

Material Options:
Platinum Electrodes and Epoxy Body

Ranges From:
0 – 200µS and up to 200mS

General Information:

  • Distilled Water 0 – 5µS
    (Organic or Inorganic Available)
  • Drinking Water 50µS – 1mS
  • Cooling Tower 900µS – 80mS

  • Seawater / Salamoia 20mS – 90mS

  • Acids / Concentrated Bases 100mS – 800mS


Conductivity Electrode
Conductivity Electrode
(Exposed Electrode)

  • Available NTC (Thermister) or PT100 (RT) Temperature Compensation

  • Immersion or ½” and ¾” Sizes Available (fits standard ½” or ¾” NPT fitting)

  • Standard Cable 13’ (4m) additional cable length available

Material Options:

  • Graphite Electrodes and PVDF Body
  • Operation Range UP to 101 PSI (7 Bars) at 158 ̊F (70 ̊C)
  • Graphite Electrodes and PVC Body
  • Operation Range UP to 101 PSI (7 Bars) at 140 ̊F (60 ̊C)
  • Stainless Steel Electrodes and PVDF Body
  • Operation Range UP to 217 PSI (15 Bars) at 266 ̊F (130 ̊C)
  • Stainless Steel Electrodes and Stainless Steel Body
  • Operation Range UP to 217 PSI (15 Bars) at 392 ̊F (200 ̊C)

Ranges From:
0 – 20µS and up to 200mS  

General Information:
  • Distilled Water 0 – 5µS
  • Drinking Water 50µS – 1mS
  • Seawater / Salamoia 20mS – 90mS
  • Acids / Concentrated Bases 100mS – 800mS

  • 0 – 40 NTU (readings in low ranges are accurate x.xx)
  • Re-Usable Calibration Solutions for up to 6 months

Operation Range:
  • UP to 7 PSI (0.5 Bars)
  • Max. Flow 10 GPH (40 LPH)

Temperature Electrodes

Temperature Electrodes

Standard Cable 13’ (4m) additional cable length available

Models:

  • High linearity
  • PT100 Sensors
  • NTC Sensors

Material Options:

  • PVDF Body Operation Range UP to 145 PSI (10 Bars) at 212 ̊F (100 ̊C)
  • Brass Body Operation Range UP to 145 PSI (10 Bars) at 212 ̊F (100 ̊C)

Electrode Holders     Electrode Holders

Electrode Holders

  • Ideal for pH, ORP, and Amperometric Membrane Cap Electrodes
  • Electrodes remain Wet at All Times
  • Hold from 1 – 6 (max. 3 Amp. Mem. Cap Elect.) Electrodes in 1 Single Holder

  • Optional: Built-In Flow Sensor and Sample Port

  • Operation Pressure and Temperature Range: up to 125 PSI (8 Bars) and 167 ̊F (75 ̊C)

  • Hose (⅜” – ½”) or ½” NPT Connections

Materials:

  • Epoxy Filter Housing
  • Acrylic (PMMA) Block

 
     
Home EMEC FloMotion Pan World Myron L. Additional Services Contacts

This site designed and maintained by SBF  2008-2009 - All rights reserved - 501(C)3 3
Proceeds go to The Special Bones Foundation  to help find a cure for OSTEOGENESIS IMPERFECTA
OI Care